Home Button  
Electric Heating

Solar Components

Air Vents
Automatic air vents for solar circuit.  Rated to high temperatures required for solar installations
Part #
Size

Package Quantity

Shipping
Weight

41000

1/2” NPT
1
1 lb.
41001
3/4” NPT
1
1 lb.
41002
1/2” NPT High Flow
1
4 lb.
       


Shut Off Valve
Connects between solar connection kit (41203) and air vent.  Rated for solar.
Part #
Size

Package Quantity

Shipping
Weight

41003

1/2” NPT M x F
1
1 lb.
       
       
       

 

3 Way Mixing Valve
Thermostatic mixing valves for tempering water coming out of solar tank.  Rated for solar.
Part #
Size

Package Quantity

Shipping
Weight

41004

1/2” Sweat
1
2 lbs.
41005
3/4” Sweat
1
2 lbs.
41006
1” Sweat
1
2 lbs.
41060
1/2” Sweat High Flow
1
3 lbs.
41061
3/4” Sweat High Flow
1
3 lbs.
41062
1” Sweat High Flow
1
3 lbs.

 

Safety Relief Valve
Prevents overpressure in solar circuit.  Rated for solar.
Part #
Pressure Rating 

Package Quantity

Shipping
Weight

41007

45 PSI
1
1 lb.
41008
60 PSI
1
1 lb.
       
       

 

Expansion Tank Connection Kit
Connects expansion tanks (41010, 41011) to pumping station (41103).  Rated for solar.
Part #

Package Quantity

Shipping
Weight

41009

1
3 lb.

 

Expansion Tanks
Provides constant system pressure and allows for expansion due to temperature increases and the creation of steam.  Rated for solar.
Part #

Size 

Package Quantity

Shipping
Weight

41010

9 Gal.
1
16 lbs.
41011
13 Gal.
1
19 lbs.
       
       

 

Solarflex
Allows for easy connection of solar thermal systems.  Flexible stainless steel piping with specialized end fittings.  Comes with one connection kit.  Rated for solar.
Part #
Size

Length

Shipping
Weight

41022

1/2”
50’
23 lbs.
41014
3/4”
50’
27 lbs.
41015
1”
50’
34 lbs.

 

Insulation Tape
1/8” x 2” x 50; roll.  Rated for solar.
Part #

Package
Quantity

Shipping
Weight

(no picture)

41018

1
1 lb.

 

UV Resistant Tape
Used for making insulation UV resistant.  2” x 30’ roll
Part #

Package
Quantity

Shipping
Weight

(no picture)

41019

1
1 lb.

 

Pipe Hangers
Hangers for Solarflex.  Screws into wood via included screws.
Part #

Size 

Package Quantity

Shipping
Weight

41026

For 1/2” Solarflex
4
1 lb.
41027
For 3/4” Solarflex
4
1 lb.
41028
For 1” Solarflex
4
1 lb.
       

 

Pumping Stations
Solar system pumping stations.  Include pressure relief valve, filling ports, check valves, 3 speed pump, temperature and pressure gages.  Single stations do not have supply side features and are designed to be used with larger systems.  Rated for solar.
Part #

Description

Shipping
Weight

41097

Single, return only
12 lbs.
41101
Dual station w/o fittings
16 lbs.
     

 

Solar Manifolds
Manifolds for HP-200 evacuated tubes.  Available in 20 or 30 tube variations.
Part #

Description

Shipping
Weight

41200

20 tube manifold
25 lbs.
41201
30 tube manifold
50 lbs.
     

 

Solar Tubes
Evacuated tubes for HP-200 manifolds.  Come 10 per box.
Part #

Description

Shipping
Weight

41202

(10) evacuated HP-200 tubes
50 lbs.
     
     

 

Connection Kit
Contains parts to connect manifold to standard smooth pipe compression fittings.  Also includes installation manuals, and well for manifold temperature sensor.
Part #

Description

Shipping
Weight

41203

Manifold connection kit
2 lbs.

 

Interconnection Kit
Connects one manifold to another.
Part #

Description

Shipping
Weight

41204

Manifold connection kit
1 lb.
     
     

 

Collector Frames
Frames for mounting HP-200 manifolds and tubes to the roof.  Several angles are available to optimize solar performance for particular application.  Frames come partially assembled for ease of installation.
Part #

Description

Shipping
Weight

41206

Parallel roof mount
15 lbs.

41205

20° Fixed angle mount
35 lbs.

41207

35°-55° Variable mount
35 lbs.

 

Solar Controllers
Electronic differential temperature controllers for solar thermal systems.  Please contact InFloor for specifics on units before purchasing.
Part #

Description

Shipping
Weight

41208

SMT-400; 4 input, 3 output
5 lbs.

41211

SMT-100; 3 input, 2 output
4 lbs.

41225

Diff controller; 5 input, 2 output
TBD

41226

Diff controller; 6 input, 3output, Data logging (SD card)
TBD

41215

Return sensor for SMT controllers, 15’ cable
1 lb.

41216

30’ extension cable for SMT sensors
1 lb.

41217

15’ tanks sensor for SMT controllers
1 lb.

 

Multi Energy Tanks
Tanks feature a tank in tank design.  Perfect for connecting solar to radiant floor heating.
Part #

Description

Shipping
Weight

41359

127 gallon, 40 gallon DHW
315 lbs.

41360

159 gallon, 60 gallon DHW
447 lbs.
     
     

 

Single Coil Tanks
Tanks for solar domestic hot water heating only.  Electric back up element included.
Part #

Size

Shipping
Weight

41370

50 gallon
Call

41371

80 gallon
CAll

41373

119 gallon
Call
     
     
     

 

Dual Coil Tanks
Tanks have 2 coils; one for putting heat in and one for taking it out.  Applications include radiant heating and DHW.  Electric back up element included.
Part #

Size

Shipping
Weight

41372

80 gallon
Call

41374

119 gallon
CAll
     
     
     
     

 

Diverting Valves
Three way valves for switching flow between applications.  All have sweat fittings.
Part #

Size 

Voltage

Switch

Shipping
Weight

41070

3/4”
24V AC
Yes
4 lb.
41071
1”
24V AC
Yes
4 lb.
41080
3/4”
24V AC
Yes
4 lb.
41081
3/4”
120V AC
Yes
4 lb.
41082
3/4”
24V AC
No
4 lb.
41083
3/4”
120V AC
No
4 lb.
41084
1”
24V AC
Yes
4 lb.
41085
1”
120V AC
Yes
4 lb.
41086
1”
24V AC
No
4 lb.
41087
1”
120V AC
No
4 lb.

© 2008 · Infloor Inc  ·  800-588-4470  ·  info@infloor.com
Hydronic Tubing
Hydronic Fittings
Hydronic Manifolds
pumps and valves
hydronic components
System Controls
mechanical boards
InfloorBoard System
Radiant Track
Tools
Tools
Tools
fasteners